Product Code: CEI-SMD / SMD-M
Smoke Motorized Dampers
صمامات دخان بمحرك
Electrically actuated smoke dampers integrated with building fire alarm and BMS systems. Fail-safe spring return to closed position on power loss. 24V or 230V actuator options.
Frame Material
Quick Query?
WhatsApp Us →
ISO 9001:2015SMACNADW144
Description
Product Description
Castle Smoke Motorized Dampers are electrically-operated dampers that close upon detection of smoke by the fire alarm system — preventing smoke circulation through HVAC ductwork. The fail-safe spring-return actuator closes the damper on power loss or smoke detection signal. Compatible with all fire alarm and BMS systems via 24V/230V actuators.
Spring-Return Fail-Safe
Actuator closes damper on power loss — guaranteed smoke containment even during electrical failure.
Fire Alarm Integration
Direct connection to fire alarm panel — closes automatically on smoke detection signal.
Low Leakage
Class II leakage per UL 555S — stainless steel jamb seals minimize smoke passage in closed position.
Dual Protection
Thermal probe at 72°C provides secondary protection independent of fire alarm system.
ISO 9001:2015 Certified
Quality management system certified by IGC, covering all stages from raw material to final delivery.
SMACNA & DW144 Compliant
Manufactured to the latest edition of SMACNA HVAC Duct Construction Standards and DW144.
Custom Sizes Available
Non-standard dimensions manufactured to project specifications with competitive lead times.
Approved by Leading Consultants
Accepted by Dar Al-Handasa, ECG, SYSTRA, Khatib & Alami and 25+ major engineering consultants.
Specifications
Technical Specifications
| Parameter | Value | Unit |
|---|---|---|
| Frame Material | Galvanized steel 1.5mm | — |
| Blade Material | Galvanized steel — multi-blade opposed | — |
| Actuator | Spring-return fail-safe — 24V AC/DC or 230V AC | — |
| Control Signal | On/Off / 0-10V / BACnet / Modbus | — |
| Smoke Rating | ES 60/120 min per BS EN 1366-10 | min |
| Leakage Class | Class II per UL 555S | — |
| Blade Seal | Stainless steel jamb seals + silicone blade seals | — |
| Rectangular Sizes | 150×150 to 1500×1500mm | mm |
| Round Sizes | Ø100 to Ø630mm | mm |
| Thermal Probe | 72°C duct-mounted probe (secondary protection) | °C |
| Mounting | In-duct / Wall / Floor | — |
| Compliance | UL 555S / BS EN 1366-10 / BS EN 13501-4 / NFPA 90A | — |
Applications
Fields of Application
Smoke compartmentation
AHU smoke isolation
Corridor smoke barriers
Stairwell pressurization
Hospital smoke zones
High-rise building smoke control
Quality Assurance
Tests & Certificates
ISO Certification
International Quality Certifications

ISO 9001:2015

ISO 14001:2015

OHSAS 18001
International Standards
SMACNA · DW144 · IGC · UL

SMACNA

DW144

IGC

UL
Duct Test
Rigorous leakage and pressure testing to SMACNA and DW144 standards.

Duct Test 01

Duct Test 02

Duct Test 03
Air Tests
Air velocity and distribution testing.

Air Test 01

Air Test 02
Get a Quote